To access the Project Dashboard, click on Project under the Dashboards section in the sidebar
The dashboard includes four tabs:
1.Consumption – Fuel Type Analysis
Analyze energy consumption based on different fuel types.
2.Cost – Financial Analytics
Gain insights into financial data related to energy usage.
3.Heatmap – Meter-wise Consumption Visualization
View detailed meter-level consumption data through an intuitive heatmap.
4. M&V- Its the process of measurement & verification
5.Information
Access detailed information about specific projects.
To view the fuel-wise analysis, click on the Consumption tab.
1.consumption Analysis Page
-The Consumption Analysis page provides a comprehensive overview of energy usage across different areas, offering both monthly and yearly breakdowns by fuel type for specific project.
-At the top of the page, individual cards summarize the total consumption for each fuel type, clearly labeled with the corresponding units.
-A filter option is available for users to select a specific building. Upon clicking ‘Apply’, the data updates accordingly to reflect the selected building’s consumption details.
– The year filter is located next to the Building’s filter, allowing you to change the year and view data from previous years as well
-Below the cards, you can view various detailed charts related to consumption analysis.
-All values displayed on the cards represent Year-to-Date (YTD) data. The specific date range for the YTD calculation is revealed when you hover over the info icon located next to the statistic
-For the last two cards Energy Reduction and Water Reduction the displayed value represents the difference between the total consumption of the previous year and the current year. For example, if we are calculating for 2024, the value shown is the total energy (or water) used in 2023 substracted from the total used in 2024.
-The red and green arrows represent the previous year’s consumption values. The color logic is as follows: if the current year’s consumption is higher than the previous year’s, a red arrow is displayed

1.1 Monthly Consumption vs. Baseline
-This chart displays the total monthly consumption and baseline for each fuel type.
-You can select different fuel types using the dropdown menu available within the chart.
-A three-line menu icon is available beside the chart.
Clicking this icon allows you to:
-
Print the chart
-
Download it as a PNG image
-
Save it as a PDF document

1.2 Energy Use Intensity (kWh/m²)
–This calculation follows the formula:
1.WUI= Water / Intensities Metadata 2 .EUI=Electricity +Chilled Water /IntensitiesMetadata
-Electricity and Chilled Water represent the combined energy consumption values of both. The Intensities Metadata values are available on the Information page
-This chart displays the Energy Usage Intensity (EUI) on a yearly basis
-In addition to the WUI label, there is a dropdown that displays all the available metadata intensities, allowing you to view the EUI across multiple years for different intensity levels
1.3 Energy Use Intensity (kWh/m²)
–This chart displays the monthly Energy Usage Intensity (EUI). Electricity and Chilled Water represent the combined energy consumption values, while the Intensities Metadata values can be found on the Information page
-All created metadata are available in the dropdown on the side.
EUI= Electricity + Chilled Water / Intensities Meta data
1.4 Water Use Intensity (IG/m²)
–This chart displays the monthly Water Usage Intensity (WUI). Water represent the Raw consumption values, while the Intensities Metadata values can be found on the Information page
Formula : WUI = Water / Intensities Meta data
-All created metadata are available in the dropdown on the side.
1.5 Utility Consumption by Years
–This chart displays raw consumption values on a monthly basis for each year, along with the appropriate unit. If you change the unit, the values will update accordingly to reflect the selected unit For all Fuel Types
A three-line menu icon is available beside the chart.
Clicking this icon allows you to:
-
Print the chart
-
Download it as a PNG image
-
Save it as a PDF document
1.6 Utility Consumption by Meter (%)
–It is the % consumption of electricity by Meter so the total consumption of all the buildings = 100%
A three-line menu icon is available beside the chart.
Clicking this icon allows you to:
-
Print the chart
-
Download it as a PNG image
-
Save it as a PDF document
* Click on the ‘Cost & Finance’ tab, which is the second tab on the Project dashboard page
2.Cost/finance Page
–The Cost/Finance page provides a comprehensive overview of Total utility cost across different areas, offering both monthly and yearly breakdowns by fuel type.
-At the top of the page, individual cards summarize the total utility cost for each fuel type, clearly labeled with the corresponding units.
-A filter option is available for users to select a specific zone. Upon clicking ‘Apply’, the data updates accordingly to reflect the selected zone’s consumption details.
Below the cards, you can view various detailed charts related to consumption analysis.
All values displayed on the cards represent Year-to-Date (YTD) data. The specific date range for the YTD calculation is revealed when you hover over the info icon located next to the statistic
2.1 Monthly Cost vs. Baseline
-This chart displays the total monthly cost and baseline for each fuel type.
-You can select different fuel types using the dropdown menu available within the chart.-A three-line menu icon is available beside the chart.
Clicking this icon allows you to:
-
Print the chart
-
Download it as a PNG image
-
Save it as a PDF document
2.2 Energy Cost Intensity (AED/m²)
EUI= Electricity +Chilled Water/ Intensities Meta data WUI= Water /metadata
-Electricity and Chilled Water represent the combined Total Utility cost values of both. The Intensities Metadata values are available on the Information page
-This chart displays the Energy Usage Intensity (EUI) on a yearly basis
-The WUI (Water Use Intensity) is calculated using the total utility cost of water. The relevant metadata can be obtained from the Information page
2.3 Energy Cost Intensity (AED/m²)
-This chart displays the monthly Energy Usage Intensity (EUI). Electricity and Chilled Water represent the combined Total utility cost values, while the Intensities Metadata values can be found on the Information page
-All created metadata are available in the dropdown on the side.
EUI = Electricity + Chilled Water / Intensities Meta data
2.4 Water Cost Intensity (AED/m²)
-This chart displays the monthly Water Usage Intensity (WUI). Water represent the Total Utility cost values, while the Intensities Metadata values can be found on the Information page
WUI = Water/ Intensities Meta data
–All created metadata are available in the dropdown on the side.
2.5 Utility Cost by Years
–This chart displays Total utility cost values on a monthly basis for each year, along with the appropriate unit. If you change the unit, the values will update accordingly to reflect the selected unit For all Fuel Types
-A three-line menu icon is available beside the chart.
Clicking this icon allows you to:
-
Print the chart
-
Download it as a PNG image
-
Save it as a PDF document
2.8 Utility Cost by Meter (%)
It is the % cost of electricity by Building . so the total of all the buildings = 100%
3.1 Click on the ‘HeatMap’ tab, which is the Third tab on the Project dashboard page
-The heatmap page displays consumption values for a selected fuel type
-On this page, you first select the fuel type. The data is displayed meter-wise, and you can also view data for each account number
Green – displays the minimum usage
Red – displays the maximum usage
White – displays no data usage
4.1 Click on the ‘M&V’ tab, which is the Fourth tab on the Project dashboard page
-This page displays the
5.1 Click on the ‘Information’’ tab, which is the Fourth tab on the Project dashboard page
– First click on Utility to see below information
-The Information page provides details on total energy consumption value for a selected year and fuel type, along with baseline comparisons.
- For the current year, the data is based on a Year-to-Date (YTD) date range.
- For all previous years, the data reflects the full calendar year
All created intensities metadata are display on information page
-Below the consumption section, the cost details are displayed. It shows the Total Utility Cost for the selected year and fuel type, along with a baseline comparison.
- For the current year, the data is based on a Year-to-Date (YTD) date range.
- For all previous years, the data reflects the full calendar year
-All intensity metadata saved for a particular year below the cost section is displayed along with the appropriate units
– After utility whatever metadata are saved that all are displayed on information with autocalculation for particular year of particular fuel type
-These metadata values are used to calculate all EUI/WUI charts
EUI = Electricity / Intensities Meta data. WUI = Water/ Intensities Meta data
-When you click on the first intensity metadata, all values including consumption and cost are updated accordingly. For the consumption calculation, the energy consumption value is used, while the cost calculation uses the total utility amount for the selected fuel type. The intensity metadata is retrieved from the metadata chart
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.